| “Ultra-supercritical 600 MW coal-fired power plant operating in the heart of Tokyo Bay, Japan is equipped with ReACT and has achieved unprecedented low emissions” |
 |
| |
Plan |
Actual |
| SOx |
10 ppm
(0.03 lb/MMbtu) |
2 ppm
(0.006 lb/MMbtu) |
NOx
(w/SCR) |
13 ppm
(0.02 lb/MMbtu) |
7 ppm
(0.01 lb/MMbtu) |
Dust
(w/ESP) |
5 mg/Nm3
(0.005 lb/MMbtu) |
2 mg/Nm3
(0.002 lb/MMbtu) |
|
|
| |
Commercial Installations / Operation
| Plant |
Gas Type |
Primary Removal Pollutant |
Start-up |
Flow Gas Rate (m3N/h) |
| Takehara #2 |
Coal |
NOx |
07/1995 |
1,200,000 [350MW] |
| Isogo #2 |
Coal |
SOx |
07/2009 |
1,800,000 [600MW] |
| A |
Sintering |
SOx / Dioxins |
08/2001 |
1,100,000 |
| A |
Sintering |
SOx / Dioxins |
11/2001 |
1,700,000 |
| B |
Sintering |
Trace substance / SOx |
12/2002 |
1,100,000 |
| B |
Sintering |
Trace substance / SOx |
12/2002 |
1,100,000 |
| C |
Sintering |
SOx/NOx |
01/2009 |
1,000,000 |
| D |
Incinerator |
NOx |
03/1994 |
32,000 |
| E |
Incinerator |
Dioxins |
05/2000 |
19,200 |
| F |
Incinerator |
Dioxins |
12/2006 |
145,000 |
| G |
Oil |
SOx, NOx |
08/1999 |
457,000 |
| H |
Other |
SOx / Dioxins |
03/2001 |
119,000 |
| I |
Other |
SOx, NOx |
04/1987 |
236,000 |
|
|
| |
|
| |
|